Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38662001

RESUMEN

INTRODUCTION: Options for soft tissue coverage in revision total knee arthroplasty (rTKA) range from primary wound closure to complex muscle flap reconstructions. The purpose of this study was to investigate the institutional experience of wound coverage options for complex soft tissue defects in rTKA. MATERIALS AND METHODS: 77 patients undergoing rTKA with complex wound closure by a single plastic surgeon were retrospectively reviewed. The average follow-up was 30.1 months. In 18 (23.4%) patients, an intraoperative decision for primary closure was made. Fifty-nine patients (76.6%) received either a local fasciocutaneous (N = 18), a medial gastrocnemius (N = 37), a free latissimus dorsi (N = 3) or a lateral gastrocnemius flap (N = 1). Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: Medial gastrocnemius flaps had significant lower cumulative revision-free survival rates than local fasciocutaneous flaps (P = 0.021) and primary closures (P < 0.001) (42.5% vs. 71.5% vs. 100%,respectively). Comparing the most common complex closure procedures medial gastrocnemius flaps had the highest rate of prolonged wound healing (29.7%) and infection/reinfection (40.5%). Infection-associated flap procedures had significant lower cumulative revision-free survival rates (30.5%) than non-infection associated flap procedures (62.8%,P = 0.047). A history of more than two prior surgeries (HR = 6.11,P < 0.001) and an age ≥ 65 years (HR = 0.30,P = 0.018) significantly increased the risk of revision. CONCLUSIONS: The results of this study indicate that primary closure -if possible- should be preferred to early proactive muscle flap coverage. Even in the hands of an experienced plastic surgeon muscle flaps have high revision and complication rates. The study highlights the need to clarify flap indications and to investigate alternative approaches.

2.
J Arthroplasty ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599529

RESUMEN

BACKGROUND: Partial or total release of the posterior cruciate ligament (PCL) is often performed intraoperatively in cruciate-retaining total knee arthroplasty (CR-TKA) to alleviate excessive femoral rollback. However, the effect of the release of selected fibers of the PCL on femoral rollback in CR-TKA is not well understood. Therefore, we used a computational model to quantify the effect of selective PCL fiber releases on femoral rollback in CR-TKA. METHODS: Computational models of nine cadaveric knees (age: 63 years, range 47 to 79) were virtually implanted with a CR-TKA. Passive flexion was simulated with the PCL retained and after serially releasing each individual fiber of the PCL, starting with the one located most anteriorly and laterally on the femoral notch and finishing with the one located most posteriorly on the medial femoral condyle. The experiment was repeated after releasing only the central PCL fiber. The femoral rollback of each condyle was defined as the anterior-posterior (AP) distance between tibiofemoral contact points at 0° and 90° of flexion. RESULTS: Release of the central PCL fiber in combination with the anterolateral (AL) fibers, reduced femoral rollback a median of 1.5 [0.8, 2.1] mm (P = 0.01) medially and by 2.0 [1.2, 2.5] mm (P = 0.04) laterally. Releasing the central fiber alone reduced the rollback by 0.7 [0.4, 1.1] mm (P < 0.01) medially and by 1.0 [0.5, 1.1] mm (P < 0.01) laterally, accounting for 47 and 50% of the reduction when released in combination with the AL fibers. CONCLUSION: Releasing the central fibers of the PCL had the largest impact on reducing femoral rollback, either alone or in combination with the release of the entire AL bundle. Thus, our findings provide clinical guidance regarding the regions of the PCL that surgeons should target to reduce femoral rollback in CR-TKA.

3.
J Arthroplasty ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38642850

RESUMEN

INTRODUCTION: Identification of femoral component debonding in the work-up of painful total knee arthroplasty (TKA) often poses a diagnostic challenge. The purpose of this study was to compare the sensitivity and specificity of radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) for identifying femoral component loosening with debonding at the time of revision of a primary TKA with a recalled polyethylene insert. METHODS: Using an institutional database, we identified all cases of revision TKA performed for this specific implant recall following a primary TKA between 2014 and 2022. Patients who had a preoperative radiograph, CT, and MRI were included (n = 77). Sensitivity, specificity, and positive and negative likelihood ratio (LR) for predicting loosening were compared among the imaging modalities, using the intraoperative evidence of implant loosening as the gold standard. RESULTS: At the time of revision surgery, the femoral component was noted to have aseptic loosening with debonding in 46 of the 77 (60%) of the TKAs. There were no significant differences in demographics in the cohort with femoral debonding compared to those with well-fixed implants. The CT demonstrated a sensitivity of 28% and a specificity of 97%, while the MRI demonstrated a sensitivity of 37% and a specificity of 94% for detecting femoral loosening due to debonding. Both CT and MRI demonstrated poor negative likelihood ratios for femoral loosening (LR 0.7). CONCLUSION: In this series of revision TKAs for a specific recalled component, neither CT nor MRI accurately diagnosed femoral component debonding. For patients who have this implant, it is imperative to interrogate the implant-cement interface intraoperatively and prepare for full revision surgery as well as marked bone loss secondary to osteolysis.

4.
Arthroplast Today ; 26: 101318, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38440289

RESUMEN

Background: Femoral neck anteversion has traditionally been measured by the angle between the distal femur posterior condylar axis (PCA) and a line drawn through the center of the femoral head and neck. While less common, the transepicondylar axis (TEA) has also been used to reference femoral neck anteversion. The purpose of this study was to compare femoral neck version of the PCA vs the TEA using computerized tomography (CT). Methods: A total of 1507 femoral CTs were included. Precise bony landmarks were established: lateral epicondyle, medial epicondyle, posteromedial condyle, posterolateral condyle, center of the femoral neck, and center of the femoral head. Femoral version was calculated between the head and neck axis and either the PCA or TEA. Differences between sex and ethnicity were evaluated. Results: The mean femoral anteversion was 12.7° ± 9.1° based on the PCA and 11.5° ± 7.9° based on the TEA (mean difference 1.2° ± 1.9°, P < .001). Males were less anteverted than females (9.8° ± 7.6° vs 13.5° ± 7.8°, P < .001). African Americans had less anteversion than other groups (8.1° ± 9.2° vs 11.5° ± 7.8°, P = .04), while Asians were more anteverted than other groups (12.1° ± 9.0° vs 11.2° ± 7.3°, P = .04). These values were referenced on the TEA. Conclusions: In this series of over 1500 femoral CT scans, the mean difference between anteversion measurements referencing the PCA and TEA was 1.2°. Native femoral version varied widely between gender and ethnic groups. Extreme femoral version, defined as <0° or >30°, was present in 11.8% of patients referencing the PCA.

5.
Hip Int ; 34(1): 15-20, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36891584

RESUMEN

INTRODUCTION: The relationship between implant type, dual mobility (DM) or fixed bearing (FB), and postoperative groin pain remains unexplored. We examined the incidence of groin pain in DM implants and compare this to a cohort of FB THA patients. METHODS: From 2006 to 2018, a single surgeon performed 875 DM THA and 856 FB THA procedures with 2.8-year and 3.1-year follow-up, respectively. Each patient received a questionnaire postoperatively and was asked if they had any groin pain (yes/no). Secondary measurements were implant characteristics such as head size, head offset, cup size, and cup-to-head ratio. Additional PROMs that were collected included: Veterans RAND 12 (VR-12), University of California Los Angeles (UCLA) activity score, Pain visual analogue scale (Pain VAS), and range of motion (ROM). RESULTS: The incidence of groin pain was 2.3% in the DM THA cohort and 6.3% in the FB THA group (p < 0.001). Also, low head offset (⩽0 mm) had a significant odds ratio (1.61) for groin pain in both cohorts. There was no significant difference in terms of revision rate between the cohorts (2.5% vs. 3.3%, p = 0.39) at the latest follow up. CONCLUSIONS: This study demonstrated a lower incidence of groin pain (2.3%) in patients with a DM bearing compared to a FB (6.3%) and a greater risk of groin pain with low head offset (<0 mm). As such, surgeons should try to recreate offset of the hip compared to the contralateral side to avoid groin pain.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Ingle/cirugía , Reoperación/efectos adversos , Diseño de Prótesis , Dolor Postoperatorio/epidemiología , Dolor Postoperatorio/etiología , Falla de Prótesis , Luxación de la Cadera/cirugía , Estudios Retrospectivos
6.
Arch Orthop Trauma Surg ; 143(11): 6927-6933, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37395854

RESUMEN

INTRODUCTION: Due to the increasing number of total hip arthroplasties (THA), the number and complexity of revision procedures are also on the rise. For complex cases such as periprosthetic joint infections with soft tissue compromise or for abductor muscle deficiencies, one of the treatment options is a gluteus maximus flap (GMF) that covers dead space and can help restore the failed abductor mechanism. The purpose of this study is to investigate the outcomes of a single-plastic surgeon's series of GMF procedures. MATERIALS AND METHODS: This retrospective review reports on 57 patients (mean follow-up 39.2 months) undergoing GMF transfers for abductor insufficiency on native hip (N = 16), for abductor insufficiency in aseptic revision THA (rTHA) (N = 16), for soft tissue defects in aseptic rTHA (N = 8) and for soft tissue defects in septic rTHA (N = 17) by a single plastic surgeon over a 10-year period. Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: The reoperation-free survival rate of GMF for abductor insufficiency in native hips was 100%. GMF procedures for soft tissue defects in septic rTHA had the lowest cumulative revision-free survival (34.3%) and highest reinfection rates (53.9%). More than three prior surgeries (HR = 2.9, p = 0.020), presence of infection (HR = 3.2, p = 0.010) and resistant organisms (HR = 3.1, p = 0.022) significantly increased the risk of revision. CONCLUSIONS: GMF is a viable option for addressing abductor insufficiency in native hip joints. However, high revision and complication rates are reported for GMF in septic rTHA. This study highlights the need to clarify the circumstances for which the flap reconstruction will be indicated.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Cirujanos , Humanos , Factor de Maduración de la Glia , Colgajos Quirúrgicos/cirugía , Articulación de la Cadera/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos
7.
Bone Jt Open ; 4(6): 432-441, 2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37272302

RESUMEN

Aims: Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model. Methods: We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition. Results: Mid-level inserts reduced varus angulations compared to PS inserts by a median of 0.4°, 0.9°, and 1.5° at 0°, 30°, and 90° of flexion, respectively, and reduced valgus angulations by a median of 0.3°, 1.0°, and 1.2° (p ≤ 0.027 for all comparisons). Mid-level inserts reduced net IE rotations by a median of 5.6°, 14.7°, and 17.5° at 0°, 30°, and 90°, respectively (p = 0.012). Mid-level inserts reduced anterior tibial translation only at 90° of flexion by a median of 3.0 millimetres (p = 0.036). With an applied varus moment, the mid-level insert decreased LCL force compared to the PS insert at all three flexion angles that were tested (p ≤ 0.036). In contrast, with a valgus moment the mid-level insert did not reduce MCL force. With an applied internal rotation moment, the mid-level insert decreased LCL force at 30° and 90° by a median of 25.7 N and 31.7 N, respectively (p = 0.017 and p = 0.012). With an external rotation moment, the mid-level insert decreased MCL force at 30° and 90° by a median of 45.7 N and 20.0 N, respectively (p ≤ 0.017 for all comparisons). With an applied anterior load, MCL and LCL forces showed no differences between the two inserts at 30° and 90° of flexion. Conclusion: The mid-level insert used in this study decreased coronal and axial plane laxities compared to the PS insert, but its stabilizing benefit in the sagittal plane was limited. Both mid-level and PS inserts depended on the MCL to resist anterior loads during a simulated clinical exam of anterior laxity.

8.
J Arthroplasty ; 38(10): 2131-2136, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37142071

RESUMEN

BACKGROUND: Despite renewed interest in cementless fixation of total knee implants, many surgeons have anecdotal concerns about slower recovery and higher early pain scores. We sought to analyze 90-day opioid utilizations, inhospital pain scores, and patient-reported outcome measures (PROMs) in patients undergoing primary cemented versus cementless total knee arthroplasty (TKA). METHODS: We retrospectively identified a cohort of opioid naïve patients undergoing primary TKA for osteoarthritis. There were 186 patients who had cementless TKAs matched 1:6 with 1,116 who received a cemented TKAs based on age (±6 years), body mass index (BMI) (±5), and sex. We compared inhospital pain scores, 90-day opioid utilizations in morphine milligram equivalents (MMEs), and early postoperative PROMs. RESULTS: The cemented and cementless cohorts had similar lowest (0.09 versus 0.08), highest (7.36 versus 7.34), and average (3.26 versus 3.27) pain scores using numeric rating scale (P > .05). They received similar inhospital (90 versus 102, P = .176), discharge (315 versus 315, P = .483), and total (687 versus 720, P = .547) MMEs. They had similar average inpatient hourly opioid consumption (2.5 versus 2.5 MMEs/hour, P = .965). Average refills 90 days postoperatively were similar in both cohorts (1.5 versus 1.4 refills, P = .893). Also, preoperative, 6-week, 3-month, delta 6-week, and delta 3-month PROMs scores were similar between cemented and cementless cohorts (P > .05) CONCLUSION: This matched study demonstrated similar in-hospital pain scores and opioid utilization, total MMEs prescribed within 90 days, and PROMs at 6 weeks and 3 months postoperatively between cemented and cementless TKAs. LEVEL OF EVIDENCE: III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Analgésicos Opioides/uso terapéutico , Estudios Retrospectivos , Pacientes Internos , Dolor
9.
J Arthroplasty ; 38(6S): S290-S296.e1, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36907386

RESUMEN

BACKGROUND: A specific total knee arthroplasty (TKA) implant system was recently recalled for high incidence of early polymeric wear and osteolysis. We analyzed the early outcomes of aseptic revision with these implants. METHODS: We identified 202 aseptic revision TKAs of this implant system performed at a single institution between 2010 and 2020. Revision indications included aseptic loosening (n = 120), instability (n = 55), and polymeric wear/osteolysis (n = 27). Components were revised in 145 cases (72%) and isolated polyethylene insert exchange occurred in 57 cases (28%). Kaplan-Meier and Cox proportional hazards analyses were used to determine survivorship free from all-cause rerevision and rerevision risk factors. RESULTS: At 2 and 5 years, survivorship free from all-cause rerevision was 89 and 76% in the polyethylene exchange cohort versus 92 and 84% in the component revision cohort (P = .5). At 2 and 5 years, survivorship in revision with components from the same manufacturer was 89 and 80% compared to 95 and 86% in revision with components from a different manufacturer (P = .2). Among re-revisions (n = 30), cones (37%), sleeves (7%), hinge/distal femoral replacement implants were frequently used (13%). Men had increased risk for rerevision (hazard ratio = 2.3, P = .04). CONCLUSION: In this series of aseptic revision TKAs performed on a now-recalled implant system, survivorship free from rerevision was lower than expected when components from the same manufacturer were utilized, but comparable to contemporary reports when both the components were revised with an alternative implant system. Metaphyseal fixation with cones and sleeves as well as highly constrained implants was frequently utilized at time of rerevision TKA. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteólisis , Masculino , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteólisis/epidemiología , Osteólisis/etiología , Osteólisis/cirugía , Falla de Prótesis , Diseño de Prótesis , Prótesis de la Rodilla/efectos adversos , Reoperación , Polietileno , Estudios Retrospectivos , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
10.
Int Orthop ; 47(5): 1243-1247, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36864185

RESUMEN

PURPOSE: Pelvic tilt (PT) is important to consider when planning total hip arthroplasty (THA) due to its dynamic impact on acetabular orientation. The degree of sagittal pelvic rotation varies during functional activities and can be difficult to measure without proper imaging. The purpose of this study was to evaluate PT variation in the supine, standing, and seated positions. METHODS: A multi-centre cross-sectional study was performed that included 358 THA patients who had preo-perative PT measured from supine CT scan and standing and upright seated lateral radiographs. Supine, standing, and seated PT and associated changes between functional positions were evaluated. Anterior PT was assigned a positive value. RESULTS: In the supine position, mean PT was 4° (range, -35° to 20°), where 23% had posterior PT and 69% anterior PT. In the standing position, mean PT was 1° (range, -23° to 29°), where 40% had posterior PT and 54% anterior PT. In the seated position, mean PT was -18° (range, -43° to 47°), where 95% had posterior PT and 4% anterior PT. From standing to seated, the pelvis rotated posteriorly in 97% of cases (maximum 60°) with 16% of cases considered stiff (change ≤ 10°) and 18% of cases considered hypermobile (change ≥ 30°). CONCLUSION: Patients undergoing THA have marked PT variation in the supine, standing, and seated positions. There was wide variability in PT change from standing to seated, with 16% of patients considered stiff and 18% considered hypermobile. Functional imaging should be performed on patients prior to THA to allow for more accurate planning.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Estudios Transversales , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Postura , Pelvis/cirugía
11.
J Arthroplasty ; 38(6): 1172-1176, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36878437

RESUMEN

BACKGROUND: Dual mobility (DM) liners were introduced to reduce instability in total hip arthroplasty. They were found to allow for motion predominantly at the femoral head and the inner bearing of the acetabular liner; however, little is known if this motion is sufficient to alter polyethylene material characteristics. We assessed cross-link (XL) density and oxidation index (OI) measurements of the inner and outer bearing articulations. METHODS: Thirty-seven DM liners were collected with a duration of implantation greater than 2 years. Clinical and demographic data were collected from a chart review. A cylinder was cored from the apex of each liner and cut into 4.5 mm long inner and outer diameter segments for XL density swell ratio testing. The OI was measured from sagittal 100 µm microtome slices using Fourier transform infrared spectroscopy. Student's t-tests were used to determine differences in OI and XL density between the bearings. Spearman's correlation assessed relationships between patient demographics, OI, and XL density. Duration of implantation for the cohort was a mean of 35 (range, 24-96) months. RESULTS: The inner and outer bearing had similar median XL densities (0.17 mol/dm3 versus 0.17 mol/dm3, P = .6). The inner bearing had an increased OI when compared to the outer bearing (0.16 versus 0.13, P = .008). The OI was inversely correlated with XL density (r = -0.50, P = .002). CONCLUSION: Small differences were found in oxidation between the inner and outer bearing of the DM construct. Failures at an average of 3 years indicate low levels of oxidation, unlikely to impact the mechanical properties of the material.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Polietileno , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Polietileno/química , Diseño de Prótesis , Falla de Prótesis
12.
J Arthroplasty ; 38(6S): S190-S195, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813213

RESUMEN

BACKGROUND: Knee instability is a leading cause of dissatisfaction following total knee arthroplasty (TKA). Instability can involve abnormal laxity in multiple directions including varus-valgus (VV) angulation, anterior-posterior (AP) translation, and internal-external rotation (IER). No existing arthrometer objectively quantifies knee laxity in all three of these directions. The study objectives were to verify the safety and assess reliability of a novel multiplanar arthrometer. METHODS: The arthrometer utilized a five degree-of-freedom instrumented linkage. Two examiners each conducted two tests on the leg that had received a TKA of 20 patients (mean age 65 years (range, 53-75); 9 men, 11 women), with nine and eleven distinct patients tested at 3-month and 1-year postoperative time points, respectively. AP forces from -10 to 30 Newtons, VV moments of ±3 Newton-meters, and IER moments of ±2.5 Newton-meters were applied to each subject's replaced knee. Severity and location of knee pain during testing were assessed using a visual analog scale. Intraexaminer and interexaminer reliabilities were characterized using intraclass correlation coefficients. RESULTS: All subjects successfully completed testing. Pain during testing averaged 0.7 (out of possible 10; range, 0-2.5). Intraexaminer reliability was >0.77 for all loading directions and examiners. Interexaminer reliability and 95% confidence intervals were 0.85 (0.66-0.94), 0.67 (0.35-0.85), and 0.54 (0.16-0.79) in the VV, IER, and AP directions, respectively. CONCLUSION: The novel arthrometer was safe for evaluating AP, VV, and IER laxities in subjects who had received TKA. This device could be used to examine relationships between laxity and patient perceptions of knee instability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación , Masculino , Humanos , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Reproducibilidad de los Resultados , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular
13.
J Arthroplasty ; 38(6S): S363-S367, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36813214

RESUMEN

BACKGROUND: Fractures of the polyethylene post are a rare but known complication after posterior-stabilized (PS) total knee arthroplasty (TKA). We evaluated the polyethylene and patient characteristics for 33 primary PS polyethylene components that were revised with fractured posts. METHODS: We identified 33 PS inserts revised between 2015 and 2022. Patient characteristics collected included age at index TKA, sex, body mass index, length of implantation (LOI), and patient-reported details on events surrounding the post fracture. Implant characteristics recorded were manufacturer, cross-linking properties (highly cross-linked polyethylene [XLPE] versus ultra-high molecular weight polyethylene [UHMWPE]), wear characteristics based on subjective scoring of the articular surfaces and scanning electron microscopy (SEM) of fracture surfaces. Mean age at index surgery was 55 years (range, 35 to 69), mean body mass index was 29.5 (range, 18.5 to 37.2), and mean LOI was 10.0 (range, 4 to 26). RESULTS: Total surface damage scores were significantly higher in the UHMWPE group versus the XLPE group (57.3 versus 44.2, P = .003). SEM demonstrated fracture initiation at the posterior edge of the post in 10 of 13 cases. UHMWPE fracture surfaces posts had more tufted, irregularly clamshell features, while XLPE posts had more precise clamshell marking and a diamond pattern in the region of acute, final fracture. CONCLUSION: Characteristics of PS post fracture differed between XLPE and UHMWPE implants, with fractures occurring in the XLPE with less generalized surface damage, after a shorter LOI, and with SEM evaluation indicative of a more brittle fracture pattern.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas Óseas , Prótesis de la Rodilla , Polietileno , Adulto , Anciano , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fracturas Óseas/cirugía , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Falla de Prótesis
14.
Arch Orthop Trauma Surg ; 143(2): 785-789, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34546422

RESUMEN

INTRODUCTION: In the acute phase of COVID-19, elevated D-dimer levels indicate a hypercoagulable state putting the patients at increased risk for venous thromboembolic disease (VTE). It is unclear, if prior COVID-19 disease increases the risk for VTE after total joint arthroplasty (TJA) and if D-dimer levels can be used to identify patients at risk. MATERIALS AND METHODS: D-Dimer levels of 313 consecutive SARS-CoV-2 IgG-positive and 2,053 -negative patients undergoing TJA between 05/20 and 12/20 were evaluated. D-Dimer levels were divided into three groups: < 200 ng/ml, 200-400 ng/ml, and > 400 ng/ml D-dimer units (DDU). 277 SARS-CoV-2 IgG-positive patients underwent a Doppler ultrasound to rule out deep-vein thrombosis (DVT) 4-6 weeks after TJA. RESULTS: D-Dimer levels did not differ significantly between SARS-CoV-2 IgG-positive and -negative patients (p value 0.53). Among SARS-CoV-2 IgG-negative patients, 1687 (82.17%) had D-dimer levels < 200 ng/ml, 256 (12.47%) between 200 and 400 ng/ml, and 110 (5.36%) > 400 ng/ml. Of the SARS-CoV-2 IgG-positive patients, 257 (83.71%) had D-dimer levels < 200 ng/ml, 34 (11.07%) between 200 and 400 ng/ml, and 16 (5.21%) > 400 ng/ml. A postoperative DVT was detected in nine patients (2.9%) in the SARS-CoV-2 IgG-positive group and a PE in one patient (0.3%). 7/229 patients with < 200 ng/ml (3.1%), 1/28 patients (3.6%) with 200-400 ng/ml and 1/9 patients (11.1%) with D-dimer levels > 400 ng/ml had a DVT or PE (p = 0.43). CONCLUSIONS: The findings of this investigation suggest there is no difference in D-dimer levels between SARS-CoV-2 IgG-positive and -negative patients undergoing TJA. Although there is a trend for increased VTE rates with increased D-dimer levels, routine D-dimer testing is not recommended based on the current data. SARS-CoV-2 IgG-positive patients have a low risk of VTE in the current study.


Asunto(s)
COVID-19 , Tromboembolia Venosa , Trombosis de la Vena , Humanos , COVID-19/complicaciones , Tromboembolia Venosa/etiología , SARS-CoV-2 , Trombosis de la Vena/etiología , Artroplastia/efectos adversos
15.
Arch Orthop Trauma Surg ; 143(3): 1579-1591, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35378597

RESUMEN

INTRODUCTION: Elective orthopedic care, including in-person office visits and physical therapy (PT), was halted on March 16, 2020, at a large, urban hospital at the onset of the local COVID-19 surge. Post-discharge care was provided predominantly through a virtual format. The purpose of this study was to assess the impact of postoperative care disruptions on early total knee arthroplasty (TKA) outcomes, specifically 90-day complications, 120-day rate of manipulation under anesthesia (MUA) and 1-year patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Institutional records were queried to identify 624 patients who underwent primary, unilateral TKA for osteoarthritis and who were discharged home between 1/1/20 and 3/15/20. These patients were compared to 558 controls discharged between 1/1/19 and 3/15/2019. Cohort demographics and in-hospital characteristics were equivalent apart from inpatient morphine milligram equivalent (MME) consumption. Patient-reported access to PT (p < 0.001) and post-discharge care (p < 0.001) were worse among study patients. Study patients were prescribed fewer post-discharge PT sessions (19.8 vs. 23.5; p < 0.001) and utilized telehealth more frequently (p < 0.001). Mann-Whitney U, T, Fisher's Exact, and chi-squared tests were used to compare outcomes. RESULTS: Ninety-day CMS complications were lower among study patients (3.5% vs. 5.9%; p = 0.05). Rates of MUA were similar between groups. Study patients reported similar PROMs and marginally inferior VR-12 mental and LEAS functional outcomes at 1 year. CONCLUSION: Disruptions to elective orthopedic care in March 2020 seemed to have had no major consequences on clinical outcomes for TKA patients. Our findings question the usefulness of pre-pandemic post-discharge protocols, which may over-emphasize in-person visits and PT.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , COVID-19 , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cuidados Posoperatorios , Cuidados Posteriores , Alta del Paciente , Medición de Resultados Informados por el Paciente , Estudios Retrospectivos
16.
Arch Orthop Trauma Surg ; 143(1): 311-315, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34302523

RESUMEN

INTRODUCTION: A history of COVID-19 (Coronavirus Disease 2019), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may have an impact on hemoglobin and ferritin levels predisposing patients to increased blood transfusion requirements following total joint arthroplasty (TJA). The current study compares ferritin levels, hemoglobin levels, and transfusion rates between SARS-CoV-2 IgG positive and SARS-CoV-2 IgG negative TJA patients. MATERIALS AND METHODS: Preoperative ferritin levels, pre- and postoperative hemoglobin levels, postoperative change in hemoglobin, and transfusion rates of 385 consecutive SARS-CoV-2 IgG positive patients undergoing TJA were compared to those of 5156 consecutive SARS-CoV-2 IgG negative patients undergoing TJA. RESULTS: Preoperative hemoglobin levels were significantly lower in SARS-CoV-2 IgG positive patients [13.3 g/dL (range 8.9-17.7 g/dL)] compared to 13.5 g/dl (7.3-18.3 g/dL; p value 0.03). Ferritin levels were significantly lower in SARS-CoV-2 IgG positive patients (mean of 106.1 ng/ml (2.1-871.3.3 ng/ml) vs. 123.7 ng/ml (1.4-1985 ng/ml) (p value 0.02)). Hemoglobin on postoperative day (POD) one, after four-six weeks, and transfusion rates did not differ between the two groups. CONCLUSION: Although preoperative hemoglobin and ferritin levels are lower in SARS-CoV2 IgG positive patients, there was no difference in hemoglobin on POD one, recovery of hemoglobin levels at four-six weeks postoperatively, and transfusion rates after surgery. Routine ferritin testing prior to TJA is not recommended in SARS-CoV-2 IgG positive patients.


Asunto(s)
COVID-19 , Ferritinas , Hemoglobinas , Humanos , Transfusión Sanguínea , Ferritinas/sangre , Hemoglobinas/análisis , Hemorragia , Inmunoglobulina G , SARS-CoV-2 , Periodo Preoperatorio
17.
J Knee Surg ; 36(1): 6-17, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33932947

RESUMEN

Lymphocyte transformation testing (LTT) is often used in the workup for possible metal allergy after total knee arthroplasty (TKA) but the correlation of this test with other diagnostic metal-allergy findings in patients undergoing revision TKA for suspected metal allergy has not been established. A single-center, single-surgeon cohort of 19 TKAs in which both components were revised for presumed implant-related metal allergy based on history, physical, and LTT testing, to nonnickel-containing implants were retrospectively identified. Histopathologic samples obtained intraoperatively were semiquantitatively analyzed using both the Hospital for Special Surgery (HSS) synovial pathology score and the Campbell aseptic lymphocyte-dominant vasculitis-associated lesion (ALVAL) score. As histopathology control group, we included in the study an additional cohort of 17 patients who received aseptic revision TKA and had no history of reported or tested metal sensitivity. All preoperative LTT results were highly reactive to nickel. However, this did not correlate with local periarticular tissue response in 18 of 19 cases which demonstrated a low HSS synovial score (mean: 3.8 ± 2.8, of a maximum score of 28) and the low Campbell ALVAL scores (mean: 2.5/10 ± 1.3, of a maximum score of 10). There were not any significant differences between the study group (suspected implant-related metal allergy) and the control group (nonsuspected implant-related metal allergy) in regard to (1) the Campbell score and (2) the HSS synovial inflammatory score. Knee Society Clinical Rating System (KSCRS) function score improved significantly after revision (mean postoperative increase: 34.0 ± 17. 2; p < 0.001), as well as mean visual analog scale (VAS) pain (mean postoperative decrease: 33.3 ± 26.4; p < 0.01) score. The short-term survival rate (at mean follow-up of 26.1 months) of this patient cohort was 100%. In this cohort of revised TKA patients with suspected nickel allergy based on clinical presentation and LTT positive results, intraoperative histopathology was essentially normal. However, all patients with suspected nickel allergy showed a significant clinical and functional improvement with excellent short-term survival rates. The clinical significance of a positive LTT needs further study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Hipersensibilidad , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Níquel/efectos adversos , Estudios Retrospectivos , Reoperación , Hipersensibilidad/etiología , Hipersensibilidad/cirugía , Prótesis de la Rodilla/efectos adversos
18.
Arthroplast Today ; 17: 126-131, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36082282

RESUMEN

Background: The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation may allow a better understanding of implant design and longevity. A new cementless total knee arthroplasty (TKA) was introduced, and we hypothesized that this cementless system would show similar fixation compared to a cemented system as assessed by multispectral MRI. Methods: Multiacquisition variable-resonance image combination selective MRI was performed in 20 patients implanted with a cementless TKA. A matched control group of 20 patients who had a cemented TKA was also evaluated. Each patellar, femoral, and tibial component was graded globally as well as by specific zones. The patella zones were medial, lateral, superior, and inferior. The femoral and tibial components were divided into 4 zones: anteromedial, anterolateral, posteromedial, and posterolateral. Integration grades were performed for each zone as follows: (1) normal, (2) fibrous tissue, (3) fluid interface, (4) osteolysis. A Chi-square test was performed to detect differences in level of integration grades between patients with cemented and those with cementless TKA. Results: At average 16-month follow-up, the cementless group grading noted 0/80 (0%) vs 2/76 (2.63%) patellar zones with fluid interface, 0/80 (0%) vs 26/80 (32.5%) femoral zones with fibrous tissue, and 10/80 (12.5%) vs 17/80 (21.25%) tibial zones with fibrous tissue. The analysis showed patellar (P < .001), femoral (P < .001), and tibial (P < .001) components had improved fixation and less percentage of fibrous tissue and fluid present in the cementless TKA. Conclusions: Utilizing metal suppression MRI, a newer cementless knee implant demonstrated excellent biologic fixation and improved fixation compared to the cemented group.

19.
Arthroplast Today ; 15: 210-214.e0, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35774896

RESUMEN

Background: Efficient resource management is becoming more important as the demand for total hip arthroplasty (THA) increases. The purpose of this study is to evaluate the ability of linear regression and Bayesian statistics in predicting implant size for THA using patient demographic variables. Material and methods: A retrospective, single-institution joint-replacement registry review was performed on patients who underwent primary THA from 2005 to 2019. Demographic information was obtained along with primary THA implant data. A total of 11,730 acetabular and 8536 femoral components were included. A multivariable regression model was created on a training cohort of 80% of the sample and applied to the validation cohort (remaining 20%). Bayesian posterior probability methods were applied to the training cohort and then tested in the validation cohort to determine the 1%, 5%, and 10% error tolerance thresholds. Results: The most predictive regression model included height, weight, and sex (cup: R2 = 0.57, all P < .001; stem mediolateral size [M/L]: R2 = 0.32, all P < .001). Removing weight had a minimal effect and resulted in a more parsimonious model (cup: R2 = 0.56, all P < .001; stem M/L: R2 = 0.32, all P < .001). Applying the posterior probability estimate to the validation cohort in the Bayesian model using height, weight, and sex demonstrated high accuracy in predicting the range of required implant sizes (95.3% cup and 90.4% stem M/L size). Conclusion: Implant size in THA is correlated with demographic variables to accurately predict implant size using Bayesian modeling. Predictive models such as linear regression and Bayesian modeling can be used to improve operating room efficiency, supply chain inventory management, and decrease costs associated with THA.

20.
Arthroplast Today ; 15: 19-23, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35368851

RESUMEN

We present a 67-year-old male patient who presented with insidious worsening of right hip pain over a 6-month period with clinical and radiographic evidence of severe osteoarthritis. The patient underwent a primary total hip arthroplasty where the femoral head specimen was sent to pathology as a routine specimen. Pathology results demonstrated metastatic adenocarcinoma of prostate origin. The present case emphasizes the importance of routine pathologic examination of femoral head specimens retrieved during total hip arthroplasty, particularly since this was a clinically unsuspected finding. Although cases like these are rare and the process of routine pathologic examination raises a concern for economic implications, a timely diagnosis of adenocarcinoma provides benefits for the patient, for which cost-benefit ratios are difficult to quantify.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...